Our Service Areas

Gas Fireplace, Gas Logs Service

Gas Fireplaces, Gas Inserts and Gas Log Sets

offers installation, repair, service and maintenance services for gas fireplaces, logs and hearth products in Salisbury, MD. If you have a gas fireplace, fireplace insert, gas stove, or gas logs, our service technicians have the experience to keep your system operating safely and at peak efficiency.

Salisbury, MD Gas Fireplace Installation

Salisbury, MD Gas Fireplace Repair

Salisbury, MD Gas Logs Service

Salisbury, MD Gas Stove Installation

Call us today to get your gas fireplace or hearth equipment serviced, repaired or replaced. proudly services the Salisbury, MD area.

Get Your Quote Today

Lit Pilot
MIKE & KAREN, D. SALISBURY, MD
11-26-2021
Needs Thermopile If Fireplace Keeps Shutting Itself Off
KEVIN, H. SALISBURY, MD
08-23-2021
Replaced Transformer, Pilot Assembly And Spark Module ....fireplace Still Unresponsive
MICHAEL, C. SALISBURY, MD
06-28-2021
Installed New Log Set
RICHARD, E. SALISBURY, MD
03-25-2021
Blew Out Pilot And Relit Log Set...
JONATHAN , C. SALISBURY, MD
03-25-2021
Model#6000trblp Serial#4754-100 Changed Batteries In Receiver... Cleaned Glass
SHERRY, W. SALISBURY, MD
01-19-2021
Model#6000tr Serial#33339-199 Needs Pilot Assembly
Vicki, C. Salisbury, MD
01-19-2021
Upon Arrival Customer Stated Unit Wouldn’t Cut On...cut On With Wall Switch And Unit Cut On Perfectly Several Times
STEVE & KATHLEEN, H. SALISBURY , MD
01-19-2021
Installed Pilot Assembly
JANET, H. SALISBURY, MD
12-30-2020
Lit Pilot And Showed Customer How To Operate
MATT, R. SALISBURY, MD
12-29-2020
Needs New Gas Valve And Pilot Assembly
MARK, F. SALISBURY, MD
12-24-2020
Blew Out Pilot And Tightened Thermocouple
TIM AND SANDRA, P. SALISBURY, MD
12-11-2020
Rewired Wall Switch
STEVE & KATHLEEN, H. SALISBURY , MD
12-10-2020
Installed Thermocouple
WAYNE, S. SALISBURY, MD
12-10-2020
Installed Pilot Assembly
TIMOTHY & JENNIFER, P. SALISBURY, MD
12-08-2020
Model#ga380351 Serial#gndc36e Needs Gray Robertshaw Ignition Box
JESSE, A. SALISBURY, MD
12-01-2020
Thermopile 465 Valve Coil 150.4....lit Pilot And Remote Not Syncing....use Wall Switch
GREG & CHERIE, T. SALISBURY, MD
12-01-2020
Thermopile 465
GREG & CHERIE, T. SALISBURY, MD
12-01-2020
Sych Remote
FLYOD, B. SALISBURY, MD
11-24-2020
Cleaned Receiver Posts
JOHN, A. SALISBURY, MD
11-04-2020
Serviced Propane Gas Vent Free Logs. Added Remote Control. Test Fired Unit
ED, B. SALISBURY, MD
10-09-2020
Fireplace Operating Fine
Erica, C. Salisbury, MD
08-31-2020
Firepit Pre-season Inspection To Ensure Safe Operation For The Summer.
Brian, H. Salisbury, MD
04-29-2020
Lit Pilot
HARRY & VIRGINIA, Z. SALISBURY, MD
02-27-2020
Needs Thermocouple Also Recommend Replacing Thermopile At Same Time...unit Is Shutting Off After 5min But Pilot Stays On
MATT & KELLY, J. SALISBURY, MD
02-19-2020
Replaced Spark Module Reworked Venting And Checked Operation Of Unit. Unit Worked Fine. No Issues.
COLLEEN, J. SALISBURY, MD
01-24-2020
Replaced Thermocouple. Test Fired Unit—no Further Issues Detected
TIMOTHY & JENNIFER, P. SALISBURY, MD
11-05-2019
Installed Ignitor And Unit Still Not Sparking Noticed Broken Ground Wire Also...recommend Having Mike And Or Rob Come Check Ground And Spark Module
WILLIAM, B. SALISBURY, MD
10-01-2019
Lit Pilot Customer Had Tank Re Filled
CARLETTE, T. SALISBURY, MD
09-20-2019
Showed Customer How To Cut On Fireplace
DAVID, M. SALISBURY, MD
09-17-2019
Switch Wasn't Completely Connected, Connected Switch At Gas Valve And Reconnected Fan Switch
ROBERT, N. SALISBURY, MD
09-04-2019
Cat Loosened Toggle Switch Wire Reconnected Switch And Unit Is Operating Fine...let Customer Know Thermocouple Looking Not To Good And Customer Wants To Replace Whole Pilot Assembly
SHARON, C. SALISBURY, MD
03-26-2019
Needs New Ignitor Gas Is Coming Out But Igniters Not Sparking
WILLIAM, B. SALISBURY, MD
03-08-2019
Fixed Wall Switch It Was Shorting Out And Ground Wasn't Connected
NINA, P. SALISBURY, MD
03-08-2019
Customer Was Concerned About Sound Of Fan But It Sounds Normal On High...even Blew Out Fan But Unit Is Operating Fine
PATRICIA, M. SALISBURY, MD
02-22-2019
Blew Out And Lit Pilot
TOM, A. SALISBURY , MD
02-19-2019
Customer Stated That Unit Would Cut Off And On By Itself...tightened Thermocouple And Did Time Test For 20 Min With No Problem..also Opened Damper To Get More Oxygen In Firebox
Jack, J. Salisbury, MD
01-03-2019
Rewired Remote
BILL & GRACE, G. SALISBURY, MD
12-19-2018
Installed Pilot Assembly
MARJORIE, J. SALISBURY, MD
12-19-2018
Remote Issue Customer Stated Remote Was Constantly Beeping....re Sync The Remote And Put Batteries In Correctly And No Longer Beeping
ROSANNE, O. SALISBURY, MD
12-19-2018
Gas Valve Stuck...customer Wants Price And Warranty On Gas Valve And New Unit
LYNN, H. SALISBURY, MD
12-08-2018
Upon Arrival Customer Stated Pilot Wouldn't Stay Lit...tightened Thermocouple And Blew Out Pilot And Pilot Lit But Went Back Out When Tried To Cut On....recommend Replacing Pilot Assembly.....
MARJORIE, J. SALISBURY, MD
12-08-2018
Disconnected Pilot Blew Out Good And Not Enough Gas Coming Through For Pilot Strength...pilot Lit But Very Weak...recommend Replacing Unit Or Gas Valve
NORM & JAN, C. SALISBURY, MD
12-03-2018
Upon Arrival Customer Stated They Smelled Gas And Couldn't Get Pilot Lit...found Small Leak At Appliance Connector...tightened Fitting And Lit Pilot
EUGENE, W. SALISBURY, MD
11-27-2018
Lowes Special Logset Is Burnt Out...customer Inquiries About New Logset
ANGELA, G. SALISBURY, MD
11-27-2018
Blew Out Pilot And Relit Unit
NORM & JAN, C. SALISBURY, MD
11-23-2018
Need To Order Remote...pics In Venture....also Fan Starts Making Noise Only When Front Is Closed...blew Out Several Times And As Long As Front Is Open Unit Makes No Noise...
KAREN, S. SALISBURY, MD
11-23-2018
On/off Knob Is Broken...knob Constantly Turns And Doesn't Stop...broken At Valve...recommend Replacing Or Look Into Getting New Unit
TINA, N. SALISBURY, MD
11-23-2018
Replaced Vent Screens And Lit Pilot
KELLY & JOHN, A. SALISBURY, MD
11-23-2018
Upon Arrival Customer Stated They Couldn't Get Unit Working....tried Lighting Polo And Kept Dropping Out...blew Out Pilot Cleaned Thermopile And Tightened Thermocouple And Pilot Still Dropping...recommend Replacing Pilot Assembly
STEVE, R. SALISBURY, MD
11-21-2018
Customer Stated Unit Wouldn't Come On....flipped Switch And Unit Didn't Fire Up...tapped Gas Valve And Unit Fired Right Up...gas Valve Was Stuck
JAY & MARJORIE, R. SALISBURY, MD
11-20-2018
Bad Switch. Added Remote. No Further Issues
EDWARD, R. SALISBURY, MD
11-16-2018
Installed Pilot Assembly
ROY, N. SALISBURY, MD
11-15-2018
Needs New Pilot Assembly
ROY, N. SALISBURY, MD
11-07-2018
Customer Stated Unit Wouldn't Cut On By Thermostat....i Lit Pilot Tightened Connection And Unit Works Fine...took Readings And Inlet Screw Won't Tighten...slow Leak...need Replace Screw Or Entire Gas Valve
TIMOTHY & CINDY, F. SALISBURY, MD
11-06-2018
Recommended To Customer That Unit Should Be Replaced And Customer Wants New Unit...couldn't Get Pilot Lit
CARLETTE, T. SALISBURY, MD
11-06-2018
Outlet Screw Won't Tighten Unit Has Small Leak...contacting Manufacturer To See If We Can Replace Screw...if Not Need New Gas Valve
TIMOTHY & JENNIFER, P. SALISBURY, MD
10-31-2018
Needs Pilot Assembly
MATT, D. SALISBURY , MD
10-26-2018
Upon Arrival Customer Stated Fan Wasn't Working...noticed Fan Was Turned Off...heated Sensor With Torch And Fan Is Working Fine...noticed Customer Has Short In Unit Switch Also
DEAN & ROSEANNE, B. SALISBURY, MD
10-25-2018
Unit Pilot Won't Hold....blew Out Pilot And Cleaned Thermopile...recommend Replacing Pilot Assembly
BABU & SYAMALA, C. SALISBURY, MD
10-24-2018
Unit Kept Shutting Off...realized Pilot Wasn't Hitting Thermocouple So Bent Bracket And Unit Is Running Fine
RICHARD & CHERYL, D. SALISBURY, MD
10-01-2018
Unit Is Shot...cheap Lowes, Home Depot Special...needs Replacing
JEFF, O. SALISBURY, MD
09-05-2018
Cleaned Logs, Pilot, Burner And Firebox
KEITH & CHERYL, C. SALISBURY, MD
08-08-2018
Painted Firebox And Touched Up Glass Frame
LEE & LINDA, M. SALISBURY, MD
08-03-2018
Lit Pilot And Checked For Leaks
RICHARD & CHERYL, D. SALISBURY, MD
05-30-2018
Lit Pilot And Sync Remote
HARRY & VIRGINIA, Z. SALISBURY, MD
04-13-2018
Lit Pilot And Took Readings
TOM, R. SALISBURY, MD
04-03-2018
Customer Wasn't Sure How To Work Fireplace...I Demonstrated How To Operate...customer Wants To Inquire About Getting New Logs Set This Summer...also Needs Assistance On How To Mount Gas Range...logset Model#gldf24r-vf THERMABLASTER
JANET, U. SALISBURY, MD
03-21-2018
Upon Arrival Customer Couldn't Get Pilot T Stay Lit...I Blew Out Pilot And Replaced Thermopile And Pilot Wouldn't Stay Lit...recommend Replacing Gas Valve...napoleon Model # Gi 3600n
BRENDA, P. SALISBURY, MD
03-21-2018
Installed Fan
BRENDA, L. SALISBURY, MD
02-19-2018
Upon Arrival Remote Wasn't Working...replaced Batteries In Box And Remote Is Working Fine
KEN & RUTH, G. SALISBURY, MD
02-08-2018
Gas Valve Sticking...recommend Replacing Valve Or New Unit...customer Found Dataplate And Pics Are In Venture
BARRY & JUDITH, D. SALISBURY, MD
01-09-2018
Upon Arrival Unit Wouldn't Stay On Longer Than 30 Seconds....blew Out Pilot, Cleaned Thermocouple And Thermopile....tightened Up Thermocouple And Unit Stayed Lit...noticed Wind Was Pushing Pilot Flame Away And Believe That's Why Unit Was Cutting Off..if Problem Continues Recommend A Shield For Pilot
JOHNY, D. SALISBURY, MD
01-08-2018
Upon Arrival Customer Stated That Pilot Would Light But Unit Wouldn't Stay Running...so I Lit Pilot Notice Flame Wasn't Hitting Thermopile Directly So I Adjusted The Pilot And Unit Is Up And Running Fine...
LOIS, M. SALISBURY, MD
12-28-2017
Replaced Thermocouple
JOHN, A. SALISBURY, MD
12-21-2017
Blew Out Pilot And Lit It
MARK, A. SALISBURY, MD
12-15-2017
Blew Ou And Lit Pilot
MARK, A. SALISBURY, MD
12-15-2017
Upon Arrival Pilot Was Out Customer Stated That Unit Wouldn't Fire Up So Lit Pilot And Flipped Switch And Nothing Came On...took Readings Thermopile Is 469 Inlet Pressure Is 7.89...no Valve Coil Or Outlet Cause Unit Won't Fire Up...tapped On Gas Valve And Still Nothing...recommend Replacing Gas Valve...
JAY & MARJORIE, R. SALISBURY, MD
12-07-2017
Installed Remote
DAVID, I. SALISBURY, MD
12-05-2017
Upon Arrival Unit Was Having A Delay...blew Off Burner And Unit Is Functioning Fine
Julie, B. Salisbury, MD
12-05-2017
Took Readings And Fixed Remote...unit Is Operating Fine
TOM, B. SALISBURY, MD
11-22-2017
Transformer Not Working Need Replacing
DIONNE & MAURICE, T. SALISBURY, MD
11-18-2017
Cleaned Igniter And Cut On Unit For Customer....took Readings And Valve Coil Is Low....SERVICE CALL
WILLIAM & JANET, S. SALISBURY, MD
11-14-2017
Customer Couldn't Get Unit On So I Cut Gas On, Cleaned Igniter And Unit Is Operating Fine....SERVICE CALL
FRED & PAMELA, W. SALISBURY, MD
11-14-2017
Pilot Is On But Unit Isn't Firing Up...operates By Thermostat And Thermostat Isn't Clicking Or Operating Unit...tried Jumping Unit And Still Not Firing Up...Mike Recommends Replacing Gas Valve
GRANVILLE, D. SALISBURY, MD
11-13-2017
Cleaned Vent Free Natural Gas Logs. Went Over Operation With Customer. No Other Issues Found.
MITCHELL, S. SALISBURY, MD
11-03-2017
Took Readings And Changed Batteries
HOWARD & DANA, T. SALISBURY, MD
10-25-2017
Customer Coming In To Purchase New Unit...due To Units Age And Now Needing Pilot Assembly
MATTIE, D. SALISBURY, MD
10-02-2017
Upon Arrival Noticed Power Cord Close To Fan But Fan Didn't Make Noise While Present
DEBBIE, B. SALISBURY, MD
05-15-2017
Lit Pilot
NICOLE, A. SALISBURY, MD
03-10-2017
Went Through Checked And Tighten Everything And Kept Dropping Out...tapped On Gas Valve And Stayed Lit Longer But Eventually Dropped Out Again
BRIAN, T. SALISBURY, MD
02-16-2017
Lit Pilot
BILL & JUDY, B. SALISBURY, MD
02-16-2017
Swapped Fan Out. Checked Operation. Showed Customer. No Issues Detected.
DEBBIE, B. SALISBURY, MD
02-10-2017
Found Remote Battery In Receiver And Got Unit Working Again. Fan Motor Seized Up. Needs Replacement. Will Get Price And Send To Customer.
ROLAND & MIRIAM, S. SALISBURY, MD
01-30-2017
Replaced Pilot Assembly In Log Set. Checked Millivoltage On Thermopile And Valve Coil All Good. Lit Appliance. No Issues.
ED, M. SALISBURY, MD
01-26-2017
Pilot Dirty. Cleaned Pilot And Checked All Readings Before And After. Minimum Charge.
BRIAN, V. SALISBURY, MD
01-16-2017
Tightened Thermocouple Into Gas Valve. Thermopile Reading Over 450 And VC Reading At 200. Any Further Issues Pilot Asset Needs Replacement
ED, M. SALISBURY, MD
01-13-2017
Cleaned Dirty Pilot. No Issues Detected.
RICH & SUSANNAH, D. SALISBURY, MD
12-29-2016
Found Dirty Pilot
KAELON & MELISSA, R. SALISBURY, MD
12-29-2016
Cleaned Thermocouple And Thermopile. Took Readings. Thermopile Was 587 And Valve Coil 233.1. No Further Issues Detected.
CRAIG, D. SALISBURY, MD
12-22-2016
Cleaned Direct Vent Natural Gas Fireplace. No Issues Detected.
Donny, D. Salisbury, MD
12-21-2016
Cleaned Pilot Assembly. Lit Unit. All Readings Good. No Issues Detected.
RICHARD, K. SALISBURY, MD
12-16-2016
Swapped Out Remote On Fireplace. Set Clock And Showed Agent How To Use. Unit Fired. No Issues Detected.
JUDY, T. SALISBURY, MD
12-14-2016
Install Fan Switch
ANN, J. SALISBURY, MD
11-17-2016
Clean Vent Free Heater
SARAH, L. SALISBURY, MD
11-14-2016
Installed New Remote. Readings Still Low. Recommend To Customer To Change Out Thermopile
ROXANNE, G. SALISBURY, MD
11-12-2016
Lite Pilot Gas Logs
PAT & HEATHER, T. SALISBURY, MD
10-13-2016
Clean Propane Fireplace
GLENN, B. SALISBURY, MD
09-29-2016
Reworked Gas Piping For Key Valve Thru Floor. No Issues Detected.
DONNA, F. SALISBURY , MD
09-28-2016
Cleaned Pilot And And Got Unit Operational. No Issues Detected. Added Remote To Unit. Showed Customer Operation And Unit Worked With No Issues.
ALON & ELLA, D. SALISBURY, MD
03-04-2016
Got Unit Operating, Rep,aced Batteries In Remote And Receiver. Checked And Operation Of Unit. No Issues Detected.
CHRISTOPHER, N. SALISBURY, MD
02-25-2016
Diagnosed Unit As Having A Bad Wall Switch.
ROBERT & SHARON, W. SALISBURY, MD
02-19-2016
Cleaned/ Removed Debris From Pilot Orifice.
MICKEY, C. SALISBURY, MD
02-19-2016
Cleaned/removed Debris From Pilot Orifice And Tested Unit.
MICKEY, C. SALISBURY, MD
02-19-2016
Installed New Ignitor.
KEVIN, C. SALISBURY, MD
02-19-2016
Relit Pilots On Gas Log Sets. Checked Operation Of Each, No Issues Detected.
THOMAS, M. Salisbury, MD
02-15-2016
Installed New Pilot Assy.
DURAN, H. SALISBURY, MD
02-12-2016
Installed New Thermocouple Pt# 1960-027
LARRY & JEANNETTE, M. SALISBURY, MD
02-12-2016
Lit Pilot On Stove In Club Room.
KIMBERLY & BRUCE, F. SALISBURY, MD
02-11-2016
Installed New"Z1RC" Remote Control System.
WILLIAM & SALLY, B. SALISBURY, MD
02-04-2016
Installed Board. Unit Lit And Operates Properly. No Issues Detected.
JAMES, A. SALISBURY, MD
01-29-2016
Swapped Out Gas Control Module. Fireplace Lit. No Issues.
JAMES, A. SALISBURY, MD
01-29-2016
Inspected Unit For Draft/cold Air Entering Room.
DEBBIE & HAROLD, A. SALISBURY, MD
01-29-2016
Installed New Thermopile. Unable To Test Unit,customers Propane Tank Empty. Customer Is Aware.
JD, S. SALISBURY, MD
01-28-2016
Low Gas Valve Reading May Need New Gas Valve. Check With Kingsman On Valve Number And If Possible To Warranty.
BILL, D. SALISBURY, MD
01-22-2016
Blew Out Pilot Hold And Bled Inlet Screw Gas Valve Stuck
JEFF & JOANNE, Y. SALISBURY, MD
11-09-2015
Set Up And Lit Fireplace Went Over Operation Of Unit With Customers. No Problems Detected
BILL, D. SALISBURY, MD
11-02-2015
Checked Fireplace. No Issues That I Could Find. Checked Readings. 540.2 On Thermopile. 218.1 Valve Coil. Inlet 11.27. Out,et 5.72 On Low. Recommend Changing Out Switch If Anything.
PATRICIA, D. SALISBURY, MD
11-02-2015
Tightened Thermocouple In Back Of Unit And Cleaned Orifice. Lit Unit. No Issues.
CONNIE, B. SALISBURY, MD
10-29-2015
Swapped Out Remote Control. No Ossues
MARY, M. SALISBURY, MD
10-16-2015
Lit Pilot And Changed Batteries In Remote. No Issues
DICK & BRENDA, Y. SALISBURY, MD
10-01-2015
Cleaned Logs Burner Thermopile Thermocouple Pilot Assembly
DEAN & ROSEANNE, B. SALISBURY, MD
09-17-2015
CLEANED FIREPLACE
RICHARD & CHERYL, D. SALISBURY, MD
08-07-2015
CLEANED FIREPLACE
GLENN, B. SALISBURY, MD
08-07-2015
Replaced Thermocouple
MELODY & RICHARD, M. SALISBURY, MD
08-18-2015
INSTALLED NEW REMOTE
KATHLEEN, T. SALISBURY, MD
08-19-2015
Replaced Gas Valve And Ignitor Button And Toggle Switch. Checked For Leaks And None Detected Had To Replace Pilot Line As Well. Checked Operation Of Unit. No Issues.
WILLIAM, C. SALISBURY, MD
05-18-2015
CHECKED FIREPLACE. UNIT IS IN GOOD WORKING CONDITION
Jack, J. Salisbury, MD
05-18-2015
Replaced Outside Upper Vent. Bottom Vent Needs To Be Replaced As Well. Vacuumed Out Burner Box And Exhaust Vent. Checked With Snake Camera--all Clean. Burner Split And Needs Replacement As Well
ROBERT & TAMARA, K. SALISBURY, MD
04-14-2015
Found Ignitor And On/off Switch Melted On Unit. Cut And Rewired Remote Receiver To Unit And Actuated Several Times With Remote. Added A Hi Temp Insulation On Inside Of Gas Valve To Help Mitigate The Heat Due To Fireplace Use. Removed Sand On Right Side Of Gas Valve For Sa,e Reason. Doors Must Be Open To Operate Unit. Found It Closed While Operating When Walking In. Explained To Customer.
WILLIAM, C. SALISBURY, MD
03-26-2015
Arrived And Found Spark Ignitor And Manual On/off Switch Melted And Remote Wires Melted On Top Of Gas Valve. Cut And Reattached Wires To Gas Valve And Operated Unit. Installed Piece Of Hi Temp Insulation On Inside Of Gas Valve To Help With Heat From Excessive Use. Also Cleared Some Of Sand Away On Valve Side To Help Mitigate Some Of The Heat As Well
WILLIAM, C. SALISBURY, MD
03-26-2015
Installed New Fan On Insert Unit
GREG & PENELOPE, M. SALISBURY, MD
03-17-2015
Unit Not Hooked Up To Appropriate Gas Supply With Correct Style Regulator--took Picture. Logs Not Set Up Properly Inside Unit--someone Else Has Been Inside Since Our Installation 3 Years Ago And Tried To Adjust. Recommend Complete Cleaning Of Unit To Be Able To Ascertain The Exact Problem, But Believe What I Have Seen Is Contributing To Gas Odor Renter Is Smelling.
HOLLY, W. SALISBURY, MD
03-11-2015
Removed Receiver Batteries And Put Them In Properly. Synced Remote To Receiver And Checked Operation Several Times. No Issues Detected And Went Over With Customer
JAMES & PEGGY, N. SALISBURY, MD
03-05-2015
Checked For Leaks Couldn't Check Pressure Or Readings Off Valve Found Ok
JOYCE &BRUCE, R. SALISBURY, MD
03-04-2015
Installed New Pilot Assembly Customer Did Not Provide Gas To Get Pilot Started
SUSAN, S. SALISBURY, MD
03-02-2015
Found Vent Free Box With Vent Free Logs Installed In Box. Saw Issues Of Soot From Front Door All The Way To Unit. Found Logs In Unit Not Placed Correctly Upon Arrival. Took Picture. Raised Burner Enough To Get Out Product Tags And Took Picture Of Model And Serial Number Of Unit. Found Minor Amount Of Loose Soot In Firebox And On Two Logs. Found Pilot Lit Bit Did Not Actuate Main Burner. This Unit Is Consistent With The Brand Sold In Big Box Stores Like Home Depot/Lowes And Did Not Want To Touch Or Move Anything Until And Insurance Adjuster/representative Had First Seen Unit And Home. Did Not Proceed Further Due To This Fact.
RICHARD, E. SALISBURY, MD
02-23-2015
Checked For Proper Log Placement Found Dirty Pilot And Clogged Orifice. Took Out And Cleaned. Made Sure Unit Was Running Properly.
JOSEPH & EDWINA, M. SALISBURY , MD
02-23-2015
Replaced Thermopile And Tested To Unit.
COLLEEN & JAMES, S. SALISBURY, MD
02-20-2015
Program Remote And Test To Unit
WILLIAM, C. SALISBURY, MD
02-20-2015
Replaced Gas Valve, Checked For Leaks, No Issues. Lit And Went Over With Customer
JOSEPH & ALMA, W. SALISBURY, MD
02-16-2015
Lit Pilot Light, Strong Blue And Stayed Lit. Checked Inlet Pressure, 10.87. Tightened Thermocouple A Little And Checked Actuation Of Unit To Make Sure Main Burner Wasn't Blowing Out Pilot. No Issues Detected. Let Unit Run 5 Minutes With No Issues.
LAWRENCE & REBECCA, H. SALISBURY, MD
02-16-2015
Turned Tank On And Lit Pilot. Remote Receiver Bad, Informed Customer. Going To Switch Receiver On From Below For Right Now
KAREN, W. SALISBURY, MD
02-13-2015
Tightened Thermocouple In Back Of Logset And Actuated Unit. If Unit Continues To Go Out, Will Need To Replace Pilot Assembly Or Entire Unit.
OSWALD, B. SALISBURY, MD
02-13-2015
Tightened Thermocouple Into Back Of Gas Valve. Mid Unit Continues To Cut Out, New Pilot Assembly Will He Needed
THOMAS, M. SALISBURY, MD
02-13-2015
Replaced Thermocouple
RONNIE & DIANE, P. SALISBURY, MD
02-10-2015
Replaced Therkoc
RONNIE & DIANE, P. SALISBURY, MD
02-10-2015
Found Pilot Off Tightened Thermocouple Blew Out Pilot Line. Got Pilot On And Tested
LEE & ELAINE, H. SALISBURY, MD
02-10-2015
Found Damaged Battery Pack
PHYLLIS, M. SALISBURY, MD
02-06-2015
Found Gas Off, Pilot Looks Blue. Thermocouple Looked A Little Rough Tightened Into Gas Valve Unit Ran 15-20 Minutes No Issues. Went Over With Customer
RONNIE & DIANE, P. SALISBURY, MD
01-27-2015
Replaced Logs
THOMAS, M. SALISBURY, MD
01-19-2015
Cleaned Out Pilot Burner And Thermocouple
JOHN, B. SALISBURY, MD
01-12-2015
Reprogrammed Remote And Receiver
TEENA, T. SALISBURY, MD
01-06-2015
Took Out Burner Cleaned Thermopile Thermocouple And Blew Out Pilot
DOUGLAS, W. SALISBURY, MD
12-19-2014
Replaced Thermopile And Tested
SHIRLEY, G. SALISBURY, MD
12-19-2014
Replaced Temperature Sensor For Blower.
SHARON, F. SALISBURY, MD
12-17-2014
Programmed Remote And Tested
KEN & RUTH, G. SALISBURY, MD
12-11-2014
Replace Thermopile Blew Out Polit Line And Cleaned Polit Orifice
PATRICIA, C. SALISBURY, MD
12-10-2014
Checked Gas And Gas Is On At Tank And Gas Shutoff Is On To Unit. Checked Electrical Outlet And No Power At Both Outlets. Checked Breaker Box And Nothing Tripped
CDE, P. SALISBURY, MD
12-05-2014
No Gas Coming Into Unit. Called Gas Co To Have Them Look At.
JASON & SUSAN, A. SALISBURY, MD
11-26-2014
Installed New Pilot Assembly, Lit Unit, Checked For Issues, None Found
TIMOTHY & CINDY, F. SALISBURY, MD
11-24-2014
Replaced Thermopile, Actuated Unit. No Issues
CAMERON & VICTORIA, J. SALISBURY, MD
11-24-2014
Cleaned Thermopile Thermocouple Polit Assembly Cleaned Burner And Checked Gas Pressures
DON, S. SALISBURY, MD
05-06-2014
Reprogrammed Remote To Receiver
JUSTIN & CHRISTINA, B. SALISBURY, MD
03-27-2014
Changed Batteries In Fireplace Remote Control
ALICE, P. SALISBURY, MD
03-10-2014
Relit Polit And Tested
HAROLD, B. SALISBURY, MD
02-13-2014
Relit Polit
JACK, M. SALISBURY, MD
02-05-2014
Replaced Thermocoulle
JOHN, M. SALISBURY, MD
02-05-2014
Cleaned Vent Free Fireplace, Pilot Assembly And Fan
ALFRED, H. SALISBURY, MD
01-31-2014
Cleaned Logs Burner Thermopile Thermocouple And Polit Assemblu
DON, E. SALISBURY, MD
01-21-2014
Relit Fireplace Pilot
RYAN & ANGELA, M. SALISBURY, MD
01-21-2014
Relit Polit Tested Thermopile And Thermocouple, Low Valve Coil Reading
JOHN, M. SALISBURY, MD
01-17-2014
Checked Polit Assembly Found Damaged Burner
BRUCE, H. SALISBURY, MD
01-10-2014
Replaced Thermocouple
BEATRICE, G. SALISBURY, MD
11-18-2013
Switched Out Grey Box Tested Outlets Tested Transformer
LEON, B. SALISBURY, MD
11-18-2013
Relit Polit
BEATRICE, G. SALISBURY, MD
11-11-2013
Clean Logs Burner Thermopile Thermocouple Pilot Assrmbly
BRUCE, H. SALISBURY, MD
09-23-2013
Replaced Vent Screen
LINDA, A. SALISBURY, MD
07-03-2014
Installed Blower
CAMERON & VICTORIA, J. SALISBURY, MD
11-30-2010
Cleaned Logs And Pilot Line
GARY & DEE, M. SALISBURY, MD
07-27-2010
LOW PRESSURE GAS GRILL REGULATOR REPAIR WITH EXTRA PARTS
ROGER, V. SALISBURY, MD
05-20-2010
SERVICE CALL-DIAGNOSTIC
GINGER, T. SALISBURY, MD
05-20-2010
EMPIRE VENTED/VENT-FREE SLOPE GRAZE BURNER WITH REMOTE
BARRY, S. SALISBURY, MD
05-20-2010
SERVICE CALL-DIAGNOSTIC - On/off Switch Fixed And Louver Pin Replaced Back Into The Unit
DAVID, I. SALISBURY, MD
05-20-2010
SERVICE CALL-DIAGNOSTIC - 2/2/10
EDWARD, H. SALISBURY, MD
05-20-2010
Kingsman HBZDV4224
KINGSMAN 42 FIREPLACE DECORATIVE TOP FLUE 22,000 BTU/HR PROPANE
JEFF, H. SALISBURY, MD
05-20-2010
DIMPLEX 39 BUILT-IN FIREBOX
, D. SALISBURY, MD
05-20-2010
Repaired Exterior Vent On Gas Fireplace
LOUIS & BARBARA, S. SALISBURY, MD
09-15-2014
Kingsman VGB24
Replaced Toggle Switch. Warranty Issue. No Charge
WILLIAM, C. SALISBURY, MD
12-31-1969
REPLACED TOGGLE SWITCH
WILLIAM, C. SALISBURY, MD
09-16-2014
Customer Stated Pilot Wouldn't Stay On And Unit Would Shut Off...cleaned And Tightened Thermocouple And Unit Ran Good Over 20min
DEBBIE, D. SALISBURY, MD
03-18-2019
Programmed Remote Tested To Fireplace
WILLIAM & ERIKA, C. SALISBURY, MD
09-23-2014
Converted Gas Fireplace From LP To NG, Tied In Gas And Actuated Unit. No Issues. Checked For Leaks. None Found
JOHN & KATHY, H. SALISBURY, MD
09-24-2014
Needs New Fan
AMANDA, L. SALISBURY, MD
03-19-2019
Customer Stated Unit Wouldn't Cut On So I Blew Out Pilot And Reconnected Switch And Unit Is Operating Fine
SHARINA, D. SALISBURY, MD
03-20-2019
Installed Thermocouple
DAVID, M. SALISBURY, MD
03-25-2019
410.334.3992 Call Now

©Red Barn Media Group 2024