Lit Pilots
GEORGE & DONNA, W. EASTON, MD
09-22-2020
Swapped Out Gas Valve—checked For Leaks None Detected. Ran Unit, No Issues Detected.
MASON, S. EASTON, MD
01-13-2020
Pilot Dirty. Cleaned Out Pilot And Thermopile Reading 420.2. Gas Valve Reading 83.2. Needs To Be At Least 170. Bad Gas Valve Need Proposal Sent On Parts And Labor To Replace. Heatilator M#gcdc60 S#ga1128424
MASON, S. EASTON, MD
01-03-2020
Replaced Burner And Gas Valve On Coal Basket. Checked For Leaks And Test Fired Unit. No Further Issues Detected.
JAN, B. EASTON, MD
04-01-2019
Needs New Fan Sensor...also Gas Valve As Sticking Just Something To Keep A Eye On...interested In Getting Electrician To Wire Up Wall Switches For Fan And Unit...so Fan Comes On Instead
CATHERINE, W. EASTON, MD
02-22-2019
Inst Fan Control And Sensor...ran Cord To Outside Power...need Electrician To Replace Electrical Outlet Under Unit
GEORGE , R. EASTON, MD
02-22-2019
Downstairs Bedroom Insert Pilot Won't Hold....recommend Replacing Thermopile....can't See Model Number But Serial# Is Wh-01410
GEORGE & DONNA, W. EASTON, MD
01-03-2019
Cleaned Logset . Checked Operation Of Unit. No Further Issues Detected.
JOHN, B. EASTON, MD
12-03-2018
Lit Pilot...wind Is Knocking It Out
JANE, K. EASTON, MD
11-29-2018
Cleaned Out And Lit Pilot...added Remote
ROGER, V. EASTON, MD
11-29-2018
Fan Not Working Recommend Replacing Sensor And Fan Control
GEORGE , R. EASTON, MD
11-15-2018
Customer Stated Pilot Wouldn't Stay Lit And Unit Wouldn't Come On...blew Out Pilot And Tightened Thermocouple And Unit Is Running Fine....middle Bracket On Glass Is Broken
CHARLES, W. EASTON, MD
11-15-2018
Checked Operation Of Unit. Changed Remote Batteries And Checked Operation Of Unit. No Further Issues Detected
IRMA, C. EASTON, MD
10-29-2018
Upon Arrival Noticed That Unit Was Electronic Ignition...flipped Switch And Pilot Would Light But Burner Wouldn't...blew Off Burner And Replaced Rock Wool And Unit Is Working Fine...inlet Pressure Is 8.15 Outlet Pressure Is 3.66
JOANN & THOMAS, H. EASTON, MD
12-29-2017
Changed Batteries And Cleaned Pilot...customer Getting Electrician To Come Check Power Because Fan Not Working
RICK, S. EASTON, MD
11-10-2017
Cleaned Pilot, Igniter And Flame Sensor--extremely Dirty. Checked Operation 3-4 Times And Lit Unit And Let Run 8 Minutes. No Further Issues Detected.
CHRISTINE, M. EASTON, MD
10-20-2017
Remote Receiver Bad In Wall. Replaced With Wall Switch. Checked Operation --no Issues Detected.
MARY, M. EASTON, MD
03-20-2017
Found Bad Remote. Replaced Remote. No Further Issues Detected.
Frederick, S. Easton, MD
01-20-2017
Replaced The Fan. Test Fired Unit No Issues Detected
ELIZABETH, H. EASTON, MD
09-08-2016
Replaced Fireplace Glass. No Issues Detected.
DALE, W. EASTON, MD
08-01-2016
Igniter And Flame Rod Dirty, Cleaned And Got Unit Operational. Could Not Get Glass Panel Affixed Without Need Of Special Tool. Explained To Customer And Will Schedule Time To Come Back And Reinstall.
CHRISTINE, M. EASTON, MD
07-14-2016
Replaced Batteries In Remote. Checked Operation Of Unit. No Issues Detected
JOHN & JOAN, V. EASTON, MD
04-17-2015
Tried Installing Remote Ordered From 3rd Party Online. Millivolt Remote Does Not Work With Servo Actuated Gas Valve. Took Picture And Will Be Calling Manufacturer Directly For Assistance.
THOMAS & CAROL, F. EASTON, MD
04-17-2015
FOUND ISSUE WITH FIREPLACE. CABLE ON REMOTE IS MELTED. WILL TAKE BACK RECEIVER TO OFFICE TO SEE IF WE CAN REPLACE WIRE. IF NOT GIVE PROPOSAL OF NEW REMOTE INSTALL TO CUSTOMER.
THOMAS & CAROL, F. EASTON, MD
03-19-2015
Replaced Thermocouple
MIKE & SUZAN, N. EASTON, MD
01-15-2015
Replaced Thermocouple And Tested
MIKE & SUZAN, N. EASTON, MD
01-15-2015
Smelled Gas During Operation, Found Outlet Screw On Gas Valve Open. Tightened And Checked For Leaks, None Found.
SCOTT & MAISIE, A. EASTON, MD
12-19-2014
Swapped Out Melted Remote With New One. Brought Old One Back. Nook Gas Pressure--inlet 7.27 Outlet 1.85
ED & CAROL, W. EASTON, MD
12-19-2014
Looked At Fireplace And Took Readings On Unit. Gas Valve Valve Coil, Started At 144 And Dropped To 132. Explained To Customer How Low That Was And Will Be Pricing Out New Valve And Labor
JOSEPH, C. EASTON, MD
11-21-2014
Installed Fankit
KEITH & PATRICIA, L. EASTON, MD
03-19-2014
Cleaned Logs And Burner
ELIZABETH, H. EASTON, MD
02-06-2014
Replaced Gas Logset Remote Control. Log Set Not Set Up Properly And Middle Left And Right Log Cracked. May Want To Look Into New Logset. Will Provide Mgmt Co With Pricing.
MEAGAN, F. EASTON, MD
07-08-2014
Kingsman ZDV6000
KINGSMAN VENTED GAS LOG GRATE BURNER - 86,000 BTU/HR - PROPANE
, F. EASTON, MD
05-20-2010
410.334.3992 Call Now