Pemberton Appliance


Pemberton Appliance Companystarstarstarstarhalf star4.7 / 5

175 Total Reviews Pemberton Appliance Company

Gas Fireplace, Gas Logs Service Salisbury, Maryland

Pemberton Appliance Company offers full repair and maintenance services for hearth products in Salisbury, MD. If you have a dv gas fireplace, fireplace insert, gas stove, or gas logs, our service technicians have the experience to keep your system operating safely and at peak efficiency.

Pemberton Appliance Company stocks the parts and has the experience necessary to keep your gas fired fireplace or stove running properly.


Customer stated that unit would cut off and on by itself...tightened thermocouple and did time test for 20 min with no problem..also opened damper to get more oxygen in firebox

Emily Drive Salisbury, MD
2019-01-03


Lit pilot and made sure unit working properly

WHITE COVE DR SALISBURY, MD
2018-12-21


Remote issue customer stated remote was constantly beeping....re sync the remote and put batteries in correctly and no longer beeping

FIRE FLY DR SALISBURY, MD
2018-12-19


Rewired remote

NEVINS PL SALISBURY, MD
2018-12-19


Installed pilot assembly

FIVE FRIARS RD SALISBURY, MD
2018-12-19


Gas valve stuck...customer wants price and warranty on gas valve and new unit

N PARK DR SALISBURY, MD
2018-12-08


Upon arrival customer stated pilot wouldn't stay lit...tightened thermocouple and blew out pilot and pilot lit but went back out when tried to cut on....recommend replacing pilot assembly.....

FIVE FRIARS RD SALISBURY, MD
2018-12-08


Disconnected pilot blew out good and not enough gas coming through for pilot strength...pilot lit but very weak...recommend replacing unit or gas valve

WHITTIER DR SALISBURY, MD
2018-12-03


Lowes special logset is burnt out...customer inquiries about new logset

W FAIRFIELD DR SALISBURY, MD
2018-11-27


Need to order remote...pics in venture....also fan starts making noise only when front is closed...blew out several times and as long as front is open unit makes no noise...

EQUESTRIAN DR SALISBURY, MD
2018-11-23


Replaced vent screens and lit pilot

Malden ct Salisbury, MD
2018-11-23


Blew out pilot and relit unit

WHITTIER DR SALISBURY, MD
2018-11-23


On/off knob is broken...knob constantly turns and doesn't stop...broken at valve...recommend replacing or look into getting new unit

OXBRIDGE DR SALISBURY, MD
2018-11-23


Upon arrival customer stated they couldn't get unit working....tried lighting polo and kept dropping out...blew out pilot cleaned thermopile and tightened thermocouple and pilot still dropping...recommend replacing pilot assembly

Deer Harbour Drive Salisbury, MD
2018-11-21


Customer stated unit wouldn't come on....flipped switch and unit didn't fire up...tapped gas valve and unit fired right up...gas valve was stuck

PATHFINDER CT SALISBURY, MD
2018-11-20


Bad switch. Added remote. No further issues

COULBOURNE DR SALISBURY, MD
2018-11-16


Installed pilot assembly

DUKE DR SALISBURY, MD
2018-11-15


Needs new pilot assembly

DUKE DR SALISBURY, MD
2018-11-07


Recommended to customer that unit should be replaced and customer wants new unit...couldn't get pilot lit

S MILL DR SALISBURY, MD
2018-11-06


Customer stated unit wouldn't cut on by thermostat....i lit pilot tightened connection and unit works fine...took readings and inlet screw won't tighten...slow leak...need replace screw or entire gas valve

ELK CREEK DR SALISBURY, MD
2018-11-06